- Home
- Technique Categories
- Gas Chromatography (GC)
- GC accessories
GC accessories
Product Listing
-
Product Part
-
-
Product Part
Description:
5mm ID Graphite Ferrule, captive type (graphite is contained within a metal band). Used with 5mm OD Glass Packed Columns on all models of GC, Injector and Detector Stainless Steel Column Adapters on all models of GC and also Injection Port Inlet Liners on GC17 and older model GCs. Either this Graphite ferrule or O-ring P4 is utilized together with joint set to install a glass packed column.
OUT OF STOCK5mm ID Graphite Ferrule, captive type (graphite is contained within a metal band). Used with 5mm OD Glass Packed Columns on all models of GC, Injector and Detector Stainless Steel Column Adapters on all models of GC and also Injection Port Inlet Liners on GC17 and older model GCs. Either this Graphite ferrule or O-ring P4 is utilized together with joint set to install a glass packed column.
-
Product Part
-
-
-
Product Part
-
Product Part
-
Product Part
-
Product Part
Description:
Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD (mm) Needle Tip Needle ID (mm) P/N Replacement Plunger P/N Replacement Needle P/N 5 μL − 42 23 0.63 Cone 0.11 221-75173 221-75173-01 - 10 μL √ 42 23 0.63 Cone 0.11 221-74469 - - 10 μL − 42 23 0.63 Cone 0.11 221-34618 - - 10 μL √ 42 23 0.63 Cone 0.11 221-75174 221-75174-02 221-75174-01 50 μL − 42 23 0.63 Cone 0.11 221-45243 - - 250 μL √ 42 23 0.63 Cone 0.11 221-45244 221-45244-01 -
OUT OF STOCKSyringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD (mm) Needle Tip Needle ID (mm) P/N Replacement Plunger P/N Replacement Needle P/N 5 μL − 42 23 0.63 Cone 0.11 221-75173 221-75173-01 - 10 μL √ 42 23 0.63 Cone 0.11 221-74469 - - 10 μL − 42 23 0.63 Cone 0.11 221-34618 - - 10 μL √ 42 23 0.63 Cone 0.11 221-75174 221-75174-02 221-75174-01 50 μL − 42 23 0.63 Cone 0.11 221-45243 - - 250 μL √ 42 23 0.63 Cone 0.11 221-45244 221-45244-01 -
-
Product Part
Description:
5mm ID Graphite ferrule (graphite is contained within a metal band), for 5mm OD Glass Packed Columns-Inlet Liners-Inj & Det Adapters
OUT OF STOCK5mm ID Graphite ferrule (graphite is contained within a metal band), for 5mm OD Glass Packed Columns-Inlet Liners-Inj & Det Adapters
-
Product Part
Description:
Using this septum alleviates the problem of reduced durability when the vaporizing chamber is used continuously at 450°C. Compared to the LL septum, the increase in bleed when used at high temperatures is kept at a lower level. The problem of sticking to the vaporizing chamber during continuous use at high temperatures experienced with a conventional septum has also been eliminated. Suitable for high-sensitivity analysis at high temperatures Maximum temperature (INJ setting temperature): 450°C
OUT OF STOCKUsing this septum alleviates the problem of reduced durability when the vaporizing chamber is used continuously at 450°C. Compared to the LL septum, the increase in bleed when used at high temperatures is kept at a lower level. The problem of sticking to the vaporizing chamber during continuous use at high temperatures experienced with a conventional septum has also been eliminated. Suitable for high-sensitivity analysis at high temperatures Maximum temperature (INJ setting temperature): 450°C

