Dedicated LC columns


Dedicated LC Columns for Application-Specific Separations

A dedicated LC column is engineered around a single analysis. Stationary phase, counter-ion and column dimensions are all fixed to suit one class of analyte, which means the chemistry is already resolved before the column reaches the instrument.

General-purpose columns take the opposite approach. A C18 covers a broad spread of compounds, and the trade-off is method development time spent tuning mobile phase, gradient and column temperature until the separation holds. Dedicated columns compress that stage. Shim-pack SCR-101H, for instance, separates organic acids by ion exclusion under a straightforward acidic aqueous mobile phase, with no gradient to optimise.

Reproducibility is what labs gain from it. When the chemistry is matched to the analyte, published conditions transfer cleanly between instruments and between sites, and batch-to-batch behaviour stays predictable. For methods locked into a QC schedule or a regulatory filing, that predictability is the whole point.

Shimadzu's dedicated range is organised by application, covering amino acid analysis, sugar and organic acid analysis, nucleotides, oligonucleotides and proteins, cannabis analysis, and organic acids.


Product Listing


Which Dedicated LC Column Do You Need?

Each application area maps to a named column family rather than to a general chemistry, so selection usually comes down to identifying the analyte class first.

  • Amino Acid Analysis: Shim-pack Amino-Li and Amino-Na resolve free and hydrolysed amino acids by cation exchange, with post-column OPA derivatisation and fluorescence detection.
  • Nucleotides, Oligonucleotides and Proteins: Shim-pack WAX-1 handles nucleotides and oligonucleotides, while Shim-pack WAX-2 and WCX-1 are the columns for protein work.
  • Cannabis Analysis: NexLeaf CBX Potency separates the cannabinoid panel for potency testing, and NexLeaf for Pesticides extends the same platform to residue screening.

Which Column Is Recommended for Sugar and Organic Acid Analysis?

Shimadzu recommends the Shim-pack SCR series, with the specific column determined by which half of the analysis you're running. Monosaccharides call for Shim-pack SCR-101N, SCR-101C or SCR-101P, which separate under a mixed mode of gel filtration and ligand exchange. Because selectivity shifts with the counter-ion, the cation form is chosen to suit the sugar set. Organic acids call for Shim-pack SCR-101H or SCR-102H instead, both ion exclusion columns built on an H-type sulfonated styrene polymer and run with an acidic aqueous mobile phase.

The SUGAR columns serve the same application area and sit alongside the SCR series in the Shimadzu range. Matching guard columns are available across both, and fitting one is worth the small extra cost, since polymer packings of this type are vulnerable to particulate carryover from food, beverage and fermentation matrices.

Pharmaceutical method development works to a different brief. The objective early on is selectivity screening rather than a locked method, so a dedicated column tends to come in later, once the analyte class has been confirmed.

Which LC Columns Are Popular for Pharmaceutical Method Development?

Shim-pack Scepter and Shim-pack Velox are the two Shimadzu columns most often used for pharmaceutical method development. Scepter provides C18, C8, Phenyl and PFPP chemistries on shared hardware, so selectivity can be changed without altering anything else in the method. Velox is the core-shell alternative when efficiency matters and back pressure has to stay moderate.

Dedicated columns take over once the target is defined. Shim-pack WAX-1 is the standard choice for oligonucleotide therapeutics, and Shim-pack WAX-2 or WCX-1 for charge variant analysis on biologics.

The Shim-pack Dedicated Column Families

Four families account for most dedicated LC work, three carrying the Shim-pack name and one under NexLeaf. Each is defined by its target analyte and the detection mode it was designed around.

  • Shim-pack SCR: Sugars and organic acids, with refractive index detection for saccharides and UV or post-column conductivity for acids. Its distinguishing feature is the counter-ion range, since the N, C, P, H and Ca forms deliver genuinely different selectivity from an otherwise identical column.
  • Shim-pack WAX and WCX: Nucleotides, oligonucleotides and proteins, detected by UV at 260 nm or 280 nm according to target. These are chemically bonded hydrophilic silica gel supports, which holds non-specific adsorption lower than a bare polymer ion exchanger typically manages.
  • Shim-pack Amino: Amino acids, detected by fluorescence following post-column reaction with OPA. Li-type and Na-type sulfone forms are both available, the Li form for physiological and free amino acids, the Na form for protein hydrolysates.
  • NexLeaf CBX Potency: Cannabinoids for potency testing, detected by UV or PDA. A 2.7 µm column and a 1.8 µm CBX II version share the same chemistry, so run time can be shortened without a change of phase.

UHPLC Pressure Compatibility

Particle sizes across the dedicated range run from 1.8 µm to 10 µm, so conventional HPLC and UHPLC-rated instruments are both covered. Particle size is the fastest guide to which system a column belongs on.

  • 10 µm and 7 µm: Shim-pack SCR polymer columns operate at low back pressure and run on a conventional HPLC well under 600 bar.
  • 5 µm and 3 µm: silica-based Shim-pack WAX and WCX columns stay within conventional range, though shorter and narrower formats raise pressure appreciably.
  • 2.7 µm: NexLeaf CBX Potency runs on a well-specified HPLC without requiring a UHPLC upgrade.
  • 1.8 µm: NexLeaf CBX II needs a UHPLC-rated instrument to reach the efficiency the particle size allows.

Maximum operating pressure varies by part number as much as by chemistry. Check the specification for the exact column before any method transfer, particularly when moving from a 300 mm polymer column to a short high-efficiency format.

Why Buy Dedicated LC Columns from Shimadzu

Sourcing columns from a laboratory consumables supplier removes a whole category of compatibility problem before it appears.

  • Made by the LC Instrument Manufacturer: Shim-pack columns are developed alongside Shimadzu Nexera and LC systems, so hardware fit, dead volume and pressure envelope are designed in rather than assumed.
  • Validated Application Conditions: Each column ships against published conditions covering mobile phase, flow rate, column temperature and detection, which shortens the route from delivery to a working method.
  • Online Ordering in Singapore: The dedicated LC range is available through ShopShimadzu with full part numbers, dimensions and USP designations, and availability can be checked before ordering. A GC column, vials or sample prep consumables can go on the same order, keeping a mixed-technique lab to one purchase transaction.
  • Local Technical Support: Column selection, method transfer and troubleshooting are handled by our Asia Pacific team in Singapore, so technical questions don't sit overnight waiting on another time zone.

If the right column for your analyte isn't obvious, contact our technical team or try the LC Column Selection Assist tool.

Frequently Asked Questions LC Columns

Which LC column should I use for sugar and organic acid analysis?

Shim-pack SCR-101N, SCR-101C and SCR-101P are the columns for monosaccharides, separating under a mixed mode of gel filtration and ligand exchange. Organic acids are better served by Shim-pack SCR-101H or SCR-102H, which operate by ion exclusion with an acidic aqueous mobile phase.

Which columns suit pharmaceutical method development?

Shim-pack Scepter and Shim-pack Velox are the usual starting points, with Scepter offering C18, C8, Phenyl and PFPP selectivity across shared hardware. Shim-pack WAX-1, WAX-2 and WCX-1 take over for oligonucleotide and biologics work once the analyte class is settled.

Do you offer metal-free LC columns?

Yes. Metal-free and inert columns form a separate technique category, since they're defined by flow path construction rather than by target analyte. The current range is listed under metal free columns.

Can I buy LC columns online in Singapore?

Yes. ShopShimadzu is the official Shimadzu Asia Pacific web store, and dedicated LC columns can be ordered online with local delivery. Log in to view pricing, and use Check Availability where an item is showing as out of stock.

Read More