Shim-pack Bio


Solution for Analysis of Peptides, Oligonucleotides and Biopharmaceuticals

The accurate analysis of biopharmaceuticals compounds is required for developing higher quality biopharmaceuticals. Shim-pack Bio
Diol and IEX columns will improve the accuracy of the characterization of peptides, oligonucleotide and biopharmaceuticals.


Product Brochure: Download PDF
 

Product Listing

  • Product Part
    Description:

    20×50 mm (Guard Column) for 227-31099-01 and 227-31099-02

    OUT OF STOCK

    20×50 mm (Guard Column) for 227-31099-01 and 227-31099-02

  • Product Part
    Description:

    20×50 mm (Guard Column) for 227-31100-01 and 227-31100-02

    OUT OF STOCK

    20×50 mm (Guard Column) for 227-31100-01 and 227-31100-02

  • Product Part
    Description:

    Shim-pack Bio HIC Column is a hydrophobic interaction chromatography (HIC) column packed with butyl bonded hydrophilic nonporous polymer particles (4 μm). HIC is suitable for the separation of anlaytes with slightly different hydrophobicity, such as antibody-drug conjugate (ADC) with different drug-antibody ratios (DAR). Shim-pack Bio HIC can be used for the analysis of DAR of ADC with relatively low pressure and high resolution. Need for DAR Analysis in ADCs ADCs consist of lysine and cysteine residues of a monoclonal antibody (mAb) and small-molecule drugs (Fig.1). However, since mAbs contain multiple amino acid residues involved in their binding, the mAbs are known to form heterogeneous ADCs with different binding numbers and binding sites. These heterogeneities can affect a drug's efficacy and safety, making analysis of the drug-antibody ratio (DAR) essential to determine the quality characteristics of ADCs. In addition, maintaining the distribution of DAR within a certain range enables quality assurance in ADC manufacturing.   Excellent Reproducibility to Help Calculate DAR Reproducibility of area values obtained from repeat injections (n= 6) of cysteine-conjugated ADC samples and an example of an automated DAR calculation report are shown below. (DAR can be calculated automatically using LabSolutions DB/CS custom reporting.) The Shim-pack BIO HIC, developed for biopharmaceutical analysis, makes it possible to detect slight differences in hydrophobicity of small-molecule drugs and perform rapid DAR analysis with high resolution. Download flyer

    OUT OF STOCK

    Shim-pack Bio HIC Column is a hydrophobic interaction chromatography (HIC) column packed with butyl bonded hydrophilic nonporous polymer particles (4 μm). HIC is suitable for the separation of anlaytes with slightly different hydrophobicity, such as antibody-drug conjugate (ADC) with different drug-antibody ratios (DAR). Shim-pack Bio HIC can be used for the analysis of DAR of ADC with relatively low pressure and high resolution. Need for DAR Analysis in ADCs ADCs consist of lysine and cysteine residues of a monoclonal antibody (mAb) and small-molecule drugs (Fig.1). However, since mAbs contain multiple amino acid residues involved in their binding, the mAbs are known to form heterogeneous ADCs with different binding numbers and binding sites. These heterogeneities can affect a drug's efficacy and safety, making analysis of the drug-antibody ratio (DAR) essential to determine the quality characteristics of ADCs. In addition, maintaining the distribution of DAR within a certain range enables quality assurance in ADC manufacturing.   Excellent Reproducibility to Help Calculate DAR Reproducibility of area values obtained from repeat injections (n= 6) of cysteine-conjugated ADC samples and an example of an automated DAR calculation report are shown below. (DAR can be calculated automatically using LabSolutions DB/CS custom reporting.) The Shim-pack BIO HIC, developed for biopharmaceutical analysis, makes it possible to detect slight differences in hydrophobicity of small-molecule drugs and perform rapid DAR analysis with high resolution. Download flyer