Technique Categories



Product Listing

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Column specifically tested for low-bleed performance. General -purpose columns for drugs, solvent impur i t ies, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5MS Integrated Guard Columns No leaks for a more robust method. No column connections for easier, faster maintenance. No peak distortions due to connector dead volume and thermal capacity. For column without Integral-Guard Column in this dimension, please refer to 221-75858-30 

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Column specifically tested for low-bleed performance. General -purpose columns for drugs, solvent impur i t ies, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5MS Integrated Guard Columns No leaks for a more robust method. No column connections for easier, faster maintenance. No peak distortions due to connector dead volume and thermal capacity. For column without Integral-Guard Column in this dimension, please refer to 221-75858-30 

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Column specifically tested for low-bleed performance. General -purpose columns for drugs, solvent impur i t ies, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5MS

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Column specifically tested for low-bleed performance. General -purpose columns for drugs, solvent impur i t ies, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5MS

  • Product Part
    Description:

    Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds. Equivalent to USP G43 phase. Similar phases: DB-1301, CP-1301, SPB-1301, Rtx-1301

    OUT OF STOCK

    Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds. Equivalent to USP G43 phase. Similar phases: DB-1301, CP-1301, SPB-1301, Rtx-1301

  • Product Part
    Description:

    Low-polarity phase: Crossbond silarylene phase 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Engineered to be a low-bleed GCMS column General-purpose columns - ideal for GCMS analysis of semi-volatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons Similar phases: Rtx-5Sil MS, DB-5ms UI, DB-5ms, VF-5ms, SLB-5ms, BPX-5, ZB-5MS, ZB-Semi-Volatiles, 007-5MS

    OUT OF STOCK

    Low-polarity phase: Crossbond silarylene phase 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Engineered to be a low-bleed GCMS column General-purpose columns - ideal for GCMS analysis of semi-volatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons Similar phases: Rtx-5Sil MS, DB-5ms UI, DB-5ms, VF-5ms, SLB-5ms, BPX-5, ZB-5MS, ZB-Semi-Volatiles, 007-5MS

  • Product Part
    Description:

    It includes instructions for ClickTek column connections.

    OUT OF STOCK

    It includes instructions for ClickTek column connections.

  • Product Part
    Description:

    It includes instructions for ClickTek column connections.

    OUT OF STOCK

    It includes instructions for ClickTek column connections.

  • Product Part
    Description:

    Instruction manual for the ClickTek column connection is not included. Can also be used on the GC-2030. A ClickTek adapter and ClickTek connector for FPD-2010 are included. (Can be used on both FPD-2010 and FPD-2010 Plus.)

    OUT OF STOCK

    Instruction manual for the ClickTek column connection is not included. Can also be used on the GC-2030. A ClickTek adapter and ClickTek connector for FPD-2010 are included. (Can be used on both FPD-2010 and FPD-2010 Plus.)

  • Product Part
    Description:

    Instruction manual for the ClickTek column connection is included. Cannot be used on the GC-2030. A ClickTek adapter and ClickTek connector for SPL-2010 and WBI-2010 are included.

    OUT OF STOCK

    Instruction manual for the ClickTek column connection is included. Cannot be used on the GC-2030. A ClickTek adapter and ClickTek connector for SPL-2010 and WBI-2010 are included.

  • Product Part
    Description:

    A ClickTek adapter and ClickTek connector for SPL-2025 are included. Instruction manual for the ClickTek column connection is included. Cannot be used on the GC-2030.

    OUT OF STOCK

    A ClickTek adapter and ClickTek connector for SPL-2025 are included. Instruction manual for the ClickTek column connection is included. Cannot be used on the GC-2030.

  • Product Part
    Description:

    Replacement for 221-77144-02 This kit is required for newly installing ClickTek connectors.

    OUT OF STOCK

    Replacement for 221-77144-02 This kit is required for newly installing ClickTek connectors.

  • Product Part
    Description:

    Replacement for 221-77144-03. This kit is required for newly installing ClickTek connectors.    

    OUT OF STOCK

    Replacement for 221-77144-03. This kit is required for newly installing ClickTek connectors.    

  • Product Part
    Description:

    Replacement for 221-77144-06 It includes instructions for ClickTek column connections. It is not a shared part with GC -2030. This kit is required for newly installing ClickTek connectors

    OUT OF STOCK

    Replacement for 221-77144-06 It includes instructions for ClickTek column connections. It is not a shared part with GC -2030. This kit is required for newly installing ClickTek connectors