Ion Chromatography columns

Product Listing

  • Product Part
    228-17733-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

  • Product Part
    228-17734-91

    Description: Guard column for Shim-pack IC-A1

  • Product Part
    228-17737-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

  • Product Part
    228-17738-91

    Description: Guard column for Shim-pack IC-C1. During the analysis of alkali metal ions with the Shim-pack IC-C1, it is recommended to use a pre-column Shim-pack IC-PC1 (P/N: 228-17744-91) installed between the liquid pump and the sample injector.

  • Product Part
    228-17744-91

    Description: During the analysis of alkali metal ions with the Shim-pack IC-C1, it is recommended to use a pre-column Shim-pack IC-PC1 (P/N: 228-17744-91) installed between the liquid pump and the sample injector.

  • Product Part
    228-18837-93

    Description: Guard column for Shim-pack AMINO-NA. * Dedicated for the analysis of cyanide. Please do not use it in the analysis of amino acids.

  • Product Part
    228-31076-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

  • Product Part
    228-31076-92

    Description: Guard column for Shim-pack IC-A3

  • Product Part
    228-33366-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

  • Product Part
    228-33367-91

    Description: SHIN-PACK IC-C3(S), 7um 2.0mm i.d.×100mm

  • Product Part
    228-33497-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

  • Product Part
    228-33497-92

    Description: Guard column for Shim-pack IC-C1 PEEK

  • Product Part
    228-35840-91

    Description: Dedicated column for Analysis of Sugar and Organic Acid Shim-pack SPR series has been developed for the analysis of neutral to weakly acid hydrophilic compounds. These columns are ideal for analyzing organic acids such as short-chain fatty acids, hydroxycarboxylic acids and ketocarboxylic acids, as well as trisaccharides or below and sugar alcohols. Shim-pack SPR series columns are packed with 8% crosslinked sulfonated polystyrene gel and used under the following conditions. Shim-pack SPR-H Ion exclusion chromatography column primarily for analyzing organic acids. Shim-pack SPR-Na Size exclusion chromatography column for analyzing trisaccharides or below and organic acids. Shim-pack SPR-Ca Size exclusion chromatography column mixed with ligand exchange mode for analyzing trisaccharides or below and sugar alcohols. Shim-pack SPR-Pb Size exclusion chromatography column mixed with strong ligand exchange mode, well-suited for analyzing sugar alcohols.  

  • Product Part
    228-35840-92

    Description: Dedicated column for Analysis of Sugar and Organic Acid Shim-pack SPR series has been developed for the analysis of neutral to weakly acid hydrophilic compounds. These columns are ideal for analyzing organic acids such as short-chain fatty acids, hydroxycarboxylic acids and ketocarboxylic acids, as well as trisaccharides or below and sugar alcohols. Shim-pack SPR series columns are packed with 8% crosslinked sulfonated polystyrene gel and used under the following conditions. Shim-pack SPR-H Ion exclusion chromatography column primarily for analyzing organic acids. Shim-pack SPR-Na Size exclusion chromatography column for analyzing trisaccharides or below and organic acids. Shim-pack SPR-Ca Size exclusion chromatography column mixed with ligand exchange mode for analyzing trisaccharides or below and sugar alcohols. Shim-pack SPR-Pb Size exclusion chromatography column mixed with strong ligand exchange mode, well-suited for analyzing sugar alcohols.  

  • Product Part
    228-35840-93

    Description: Dedicated column for Analysis of Sugar and Organic Acid Shim-pack SPR series has been developed for the analysis of neutral to weakly acid hydrophilic compounds. These columns are ideal for analyzing organic acids such as short-chain fatty acids, hydroxycarboxylic acids and ketocarboxylic acids, as well as trisaccharides or below and sugar alcohols. Shim-pack SPR series columns are packed with 8% crosslinked sulfonated polystyrene gel and used under the following conditions. Shim-pack SPR-H Ion exclusion chromatography column primarily for analyzing organic acids. Shim-pack SPR-Na Size exclusion chromatography column for analyzing trisaccharides or below and organic acids. Shim-pack SPR-Ca Size exclusion chromatography column mixed with ligand exchange mode for analyzing trisaccharides or below and sugar alcohols. Shim-pack SPR-Pb Size exclusion chromatography column mixed with strong ligand exchange mode, well-suited for analyzing sugar alcohols.  

  • Product Part
    228-35840-94

    Description: Dedicated column for Analysis of Sugar and Organic Acid Shim-pack SPR series has been developed for the analysis of neutral to weakly acid hydrophilic compounds. These columns are ideal for analyzing organic acids such as short-chain fatty acids, hydroxycarboxylic acids and ketocarboxylic acids, as well as trisaccharides or below and sugar alcohols. Shim-pack SPR series columns are packed with 8% crosslinked sulfonated polystyrene gel and used under the following conditions. Shim-pack SPR-H Ion exclusion chromatography column primarily for analyzing organic acids. Shim-pack SPR-Na Size exclusion chromatography column for analyzing trisaccharides or below and organic acids. Shim-pack SPR-Ca Size exclusion chromatography column mixed with ligand exchange mode for analyzing trisaccharides or below and sugar alcohols. Shim-pack SPR-Pb Size exclusion chromatography column mixed with strong ligand exchange mode, well-suited for analyzing sugar alcohols.  

  • Product Part
    228-35840-95

    Description: Dedicated column for Analysis of Sugar and Organic Acid Shim-pack SPR series has been developed for the analysis of neutral to weakly acid hydrophilic compounds. These columns are ideal for analyzing organic acids such as short-chain fatty acids, hydroxycarboxylic acids and ketocarboxylic acids, as well as trisaccharides or below and sugar alcohols. Shim-pack SPR series columns are packed with 8% crosslinked sulfonated polystyrene gel and used under the following conditions. Shim-pack SPR-H Ion exclusion chromatography column primarily for analyzing organic acids. Shim-pack SPR-Na Size exclusion chromatography column for analyzing trisaccharides or below and organic acids. Shim-pack SPR-Ca Size exclusion chromatography column mixed with ligand exchange mode for analyzing trisaccharides or below and sugar alcohols. Shim-pack SPR-Pb Size exclusion chromatography column mixed with strong ligand exchange mode, well-suited for analyzing sugar alcohols.  

  • Product Part
    228-35841-91

    Description: Guard column for Shim-pack SPR-H

  • Product Part
    228-35841-92

    Description: Guard column for Shim-pack SPR-H

  • Product Part
    228-35841-93

    Description: Guard column for Shim-pack SPR-NA

  • Product Part
    228-35841-94

    Description: Guard column for Shim-pack SPR-CA

  • Product Part
    228-35841-95

    Description: Guard column for Shim-pack SPR-PB

  • Product Part
    228-36605-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

  • Product Part
    228-36605-92

    Description: Guard column for Shim-pack IC-SC1

  • Product Part
    228-38983-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

  • Product Part
    228-38983-92

    Description: Guard column for Shim-pack IC-SA2

  • Product Part
    228-41600-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

  • Product Part
    228-41600-92

    Description: Guard column for Shim-pack IC-SA3

  • Product Part
    228-41613-93

    Description: Include 3x cartridges and 1x column holder The Shim-pack IC-GC3III is a guard column for use with the cation analysis column Shim-pack IC-C3.

  • Product Part
    228-41616-91

    Description: Ion chromatography (IC) is used for analysis of inorganic and organic ions. It is categorized as suppressor IC and non-suppressor IC. Non-suppressor IC is composed of a conventional HPLC system combined with a conductivity detector, while suppressor IC requires an extra suppressor.  

Showing 1 to 30 of 35